Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 99 Renovation of existing labs Client: Childrens Hospital | Permit type: Gas | Current use: Comm | Permit id: G43755 | Parcel: 401886000 | |||||
SCORE 99 Lab renovations Client: Childrens Hospital | Permit type: Plumbing | Current use: Comm | Permit id: Pl43756 | Parcel: 401886000 | |||||
SCORE 93 Install of water filtration system Client: Childrens Hospital | Permit type: Plumbing | Current use: Comm | Permit id: Pl65090 | Parcel: 401886000 | |||||
SCORE 100 Control work in enders building 3 5 6 7 8 10 11 12 and project named enders &; karp research backfill. Scope consists of 49 supply vav boxes 49 exhaust vav boxes powered by 120 volt circuits. 5 fume hoods 2 fan coil units and 180 alarm points. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E68468 | Parcel: 401886000 | |||||
SCORE 93 Installation of water filtration system. Dept of cardiology enders bldg Client: Childrens Hospital | Permit type: Plumbing | Current use: Comm | Permit id: Pl75354 | Parcel: 401886000 | |||||
SCORE 93 Installation of water filtration system Client: Childrens Hospital | Permit type: Plumbing | Current use: Comm | Permit id: Pl75656 | Parcel: 401886000 | |||||
SCORE 100 Provide circuits(2 -120 volt) for new fume hood in class1 div2 hazardous material room. There will be one new explosion proof light and a control package for fume hood to be installed. Mount new drive on 14th floor in place of starter for fume hood. 3 new control points to vfd. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E100449 | Parcel: 401886000 | |||||
SCORE 100 Controls to 6 fan coil units 4 reheats 30 vav and 35 misc points. Enders building 2nd and 3rd floor. Permit type: Electrical | Current use: Comm | Permit id: E144105 | |||||
SCORE 100 Control work in new cage wash area and aquatics area. Ender sub b and sub sub b. 120 volt power to vav boxes and controllers. 120 vav boxes 2 exhaust fans 15 lab package controls and misc points. Permit type: Electrical | Current use: Comm | Permit id: E144111 | |||||
SCORE 96 Interior renovations of the enders building auditorium (1st floor) including paint carpet lighting and upholstery. Permit type: Renovations -interio | Current use: Other | Permit id: Sf141017 | |||||
SCORE 82 Renovations and upgrades to finishes paint floor ceiling. Lab furniture upgrades. Permit type: Renovations -interio | Current use: Other | Permit id: Sf146050 | |||||
SCORE 100 Controls to 6 vav boxes on enders 11th floor. Steen lab en1147 1148 and 1149. Permit type: Electrical | Current use: Comm | Permit id: E150656 | |||||
SCORE 100 Replace 25 fixtures on exterior of enders building. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E171301 | Parcel: 401886000 | |||||
SCORE 100 Enders sub basement hot water sensors. Install new field equipment panel and power. Pipe and wire 12 low voltage sensors. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E188616 | Parcel: 401886000 | |||||
SCORE 100 Enders building - 5th floor - renovation consists of offices including drywall patching paint (1) new door new millwork shelving carpet medical plumbing gas modifications minor hvac and minor electrical. Client: Childrens Hospital | Permit type: Renovations -interio | Current use: Comm | Permit id: Sf196920 | Parcel: 401886000 | |||||
SCORE 100 Enders 5 renovation. Extend 120 volt circuit and install new controls on 2 new vav boxes and 4 alarm points Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E209619 | Parcel: 401886000 | |||||
SCORE 93 Filtered water cooler Client: Childrens Hospital | Permit type: Plumbing | Current use: Comm | Permit id: Pl226955 | Parcel: 401886000 | |||||
SCORE 100 Remove ph monitoring panel and replace with newer ph panel. Reuse existing 120 volt circuit feeding it. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E237988 | Parcel: 401886000 | |||||
SCORE 100 Karp 6 and 9 lab renovations. Extend 120 volt emergency circuit to 12 new controllers with 50 va transformers for vav controls and alarm controls. Provide control wiring for vavs and alarms. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E303289 | Parcel: 401886000 | |||||
SCORE 100 Enders building transformer room en 1404 and 1440. Low voltage control points on new air handling unit and metering points. New field equipment panel will be mounted. Client: Childrens Hospital | Permit type: Low voltage | Current use: Comm | Permit id: Elv306635 | Parcel: 401886000 | |||||
SCORE 100 Remove existing air handler and replacing it - burning and cutting of old lines new electrical feeds and some block work with new door within space - childrens hospital - enders building - en14. (all electrical is being completed under another project and though there may be some cross sections show Client: Childrens Hospital | Permit type: Fast track applicati | Current use: Other | Permit id: Alt308717 | Parcel: 401886000 | |||||
SCORE 100 Enders upss. Install 15 upss on 15 control system router cans. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E321064 | Parcel: 401886000 | |||||
SCORE 100 Bio repository oxygen sensing system. Install new oxygen sensing monitor and 3 strobes in room en 213-215. Power with 120 volt atc circuit or new circuit. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E339244 | Parcel: 401886000 | |||||
SCORE 100 Replacing an air handler in the ssb of the enders building. Client: Childrens Hospital | Permit type: Fast track applicati | Current use: Other | Permit id: Alt338522 | Parcel: 401886000 | |||||
SCORE 97 Demolition and installation of a new 225a panel in the enders sub sub basement for a air handeling unit Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E339766 | Parcel: 401886000 | |||||
SCORE 97 Demolition of smoke duct detector and test station and installation of a smoke duct detector Client: Childrens Hospital | Permit type: Fire alarm | Current use: Comm | Permit id: Efa339771 | Parcel: 401886000 | |||||
SCORE 100 Enders ssb ahu 914. Install new low voltage controls and 120 volts controls to new ahu. Roughly 50 new points. In conjuction with permit # alt338522 Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E340276 | Parcel: 401886000 | |||||
SCORE 100 Enders 13th fl bl-3. Extend 120 volt atc circuit to power 6 phoenix valves and install control wiring. Client: Childrens Hospital | Permit type: Electrical | Current use: Comm | Permit id: E346112 | Parcel: 401886000 |