Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Electrical permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 674255 | |||||
Use permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 545857 | |||||
Electrical permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 593228 | |||||
Alteration permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 566629 | |||||
Administrative permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 567205 | |||||
Demolition permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 476062 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 695294 | |||||
Electrical permit ![]() Client: U All No Llc | Permit status: Expired | Permit id: 580197 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 559632 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 600297 | |||||
Use permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 676499 | |||||
Plumbing permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 700072 | |||||
Plumbing permit ![]() Client: U All No Llc | Permit status: Expired | Permit id: 566256 | |||||
Alteration permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 641443 | |||||
Permit for the creation of eight (8) tenant spaces (b01 to b03 & b06 to b10) from seven (7) spaces in the basement all spaces for use as artist studio and artisan industrial. For the creation of fifteen (15) tenant spaces (101 & 103 to 116) from eleven (11) spaces on the 1st floor for uses as follows: space 103 & 104 - business/professional office, space 116 - vacant space, space 101, 105 to 115 - for use as artist studio and artisan industrial. For the creation of thirteen (13) tenant spaces (201 to 206 & 208 to 214) from five (5) spaces on the 2nd floor all spaces for use as artist studio and artisan industrial. For the creation of seventeen (17) tenant spaces (301 to 317) from two (2) spaces on the 3rd floor all spaces for use as artist studio and artisan industrial. For the creation of nine (9) tenant spaces (401 to 409) from one (1) space on the 4th floor. Spaces 401 to 406 for use as artist studio and artisan industrial, 407 to 409 for use as banquet hall for more than people (ni ![]() Client: U All No Llc | Applicant: Shawn Ward, Esq. | Permit type: Appeal | Permit status: Granted | Permit id: 28031 | |||||
Electrical permit ![]() Client: U All No Llc | Permit status: Expired | Permit id: 580197 | |||||
Electrical permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 689341 | |||||
Electrical permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 593228 | |||||
Demolition permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 476062 | |||||
Plumbing permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 729304 | |||||
Use permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 545857 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 695294 | |||||
Alteration permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 566629 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 559632 | |||||
Alteration permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 641443 | |||||
Suppression permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 600297 | |||||
Use permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 676499 | |||||
Mechanical permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 707721 | |||||
Plumbing permit ![]() Client: U All No Llc | Permit status: Expired | Permit id: 566256 | |||||
Administrative permit ![]() Client: U All No Llc | Permit status: Completed | Permit id: 567205 | |||||
Administrative permit ![]() Client: U All No Llc | Permit status: Active | Permit id: 706597 | |||||
Permit for the creation of eight (8) tenant spaces (b01 to b03 & b06 to b10) from seven (7) spaces in the basement all spaces for use as artist studio and artisan industrial. For the creation of fifteen (15) tenant spaces (101 & 103 to 116) from eleven (11) spaces on the 1st floor for uses as follows: space 103 & 104 - business professional office, space 116 - vacant space, space 101, 105 to 115 - for use as artist studio and artisan industrial. For the creation of thirteen (13) tenant spaces (201 to 206 & 208 to 214) from five (5) spaces on the 2nd floor all spaces for use as artist studio and artisan industrial. For the creation of seventeen (17) tenant spaces (301 to 317) from two (2) spaces on the 3rd floor all spaces for use as artist studio and artisan industrial. For the creation of nine (9) tenant spaces (401 to 409) from one (1) space on the 4th floor. Spaces 401 to 406 for use as artist studio and artisan industrial, 407 to 409 for use as banquet hall for more than people (ni ![]() Client: U All No Llc | Applicant: Shawn Ward, Esq. | Permit type: Appeal | Permit status: Granted | Completion date: January 23, 2017 | Permit id: 28031 | |||||
SCORE 89 Main distribution switchgear, tennant fit out of lights, recepts, panels, sub feeders as per 2008 nec (east district) install fire alarm system as per nfpa72 ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 689341 | |||||
SCORE 82 Repair to existing class "b" fa system,existing wiring of flow sws,tamper sws,& fire pump controls,repair & connect electrical. Install new primary & secondary service,service equipment,sub feeds,panels & wiring for fit out (commercial) ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: October 29, 2015 | Permit id: 554008 | |||||
SCORE 100 Relocation of 15 sprinkler heads (mixed use) ![]() ![]() Client: U All No Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: October 11, 2014 | Permit id: 559632 | |||||
SCORE 96 Replacement of existing fixtures only 5-hand sink, 2-wc, 2-lavs, 1-stand up shower deverter (comm) ![]() ![]() Client: U All No Llc | Permit type: Plumbing permit | Permit status: Expired | Completion date: April 14, 2015 | Permit id: 566256 | |||||
SCORE 78 Repairing approx 52 broken windows throughout the first, swecond, and third floor of the 3525 1st building ![]() ![]() Client: U All No Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: March 16, 2015 | Permit id: 566629 | |||||
SCORE 89 Install 4 - 100amp three phase panels onne on each floor basement throuth to 3rd floor with 100amp feeders as per 2008 nec (east district) ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: October 12, 2016 | Permit id: 580198 | |||||
SCORE 89 Extension 0f 400a service to feed 150kva delta to wye transformer, 400a mdp panel, install 5 200a feeders to 5 200a panels (bsmt,1,2,3,4 floors), install 40a 2 pole & 3 pole breakers to refeed existing units. ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: May 16, 2015 | Permit id: 593228 | |||||
SCORE 89 Close circuti television system for security system, 8 exterior camaras, 8 interior cameras, 1 - 16 channel dvr and 1 - 32" monitor as per 2008 nec (east district) ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2017 | Permit id: 580197 | |||||
Amendment to ap# 549724 to reflect changes throughout the structure, all alterations to be done per approved plans and documentation. Work to include level iii alterations to an existing building for the use of artist studios, business and professional offices and personal services from the basement through the third floor level. Alterations to include the erection of fire rated walls for tenant separation, provide accessibility improvements and finishes throughout. Please see attached affidavit of restricted use for the fourth floor level. Building is fully sprinklered. All work to be done per approved plans, if field conditions vary contact design professional prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire supression work. ![]() Client: U All No Llc | Permit type: Administrative permit | Permit status: Completed | Completion date: November 14, 2016 | Permit id: 567205 | |||||
SCORE 100 Comverting existing fire sprinkler system from wet to dry. ![]() ![]() Client: U All No Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: February 2, 2016 | Permit id: 600297 | |||||
SCORE 86 Run 5 new circuit to install 71 new light fixtures out side of bldg as per 2008 nec (commercial) ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 607860 | |||||
SCORE 78 Phase 2 work only: interior and exterior alterations with structural modifications and repairs, slab infill & framing for storefront, terrace and facade repairs. Additional studio tenant fit outs, egress improvements, fire safety improvements, accessibility upgrades, new finishes, window replacement for main building as per designers plans. 4th floor to remain vacant as per prior affidavit of restricted use. Separate permits required for mechanical, electrical, plumbing and fire suppression work. In conjunction with prior phase 1 permit ap#549724 ![]() ![]() Client: U All No Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 641443 | |||||
SCORE 89 New service 13. 2kv to 480 277 volt. 1600amps primary and secondary cabling only per 2008 nec (art studio) ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 674255 | |||||
Basement - for the creation of eight (8) tenant spaces (b01 to b03 & b06 to b10) from seven (7) spaces all spaces for use as artist studio and artisan industrial. 1st floor - for the creation of fifteen (15) tenant spaces (101 & 103 to 116) from eleven (11) spaces for uses as follows: space 103 & 104 ? Business professional office, space 116 ? Vacant space (use registration permit require prior to occupancy) , space 101, 105 to 115 - for use as artist studio and artisan industrial. 2nd floor - for the creation of thirteen (13) tenant spaces (201 to 206 & 208 to 214) from five (5) spaces. All spaces for use as artist studio and artisan industrial. 3rd floor - for the creation of seventeen (17) tenant spaces (301 to 317) from two (2) spaces. All spaces for use as artist studio and artisan industrial. 4th floor - for the creation of nine (9) tenant spaces (401 to 409) from one (1) space. Spaces 401 to 406 for use as artist studio and artisan industrial; 407 to 409 for use as banquet hall ![]() Client: U All No Llc | Permit type: Use permit | Permit status: Completed | Completion date: August 15, 2016 | Permit id: 676499 | |||||
SCORE 78 For level iii alterations to an existing building for the use of artist studios, business and professional offices and personal services from the basement through the third floor level. Alterations to include the erection of fire rated walls for tenant separation, provide accessibility improvements and finishes throughout. Please see attached affidavit of restricted use for the fourth floor level. Building is fully sprinklered. All work to be done per approved plans, if field conditions vary contact design professional prior to the start of any work. For the partial resolution of l&i violation case # 438535 separate permits required for mechanical, electrical, plumbing and fire supression work. ![]() ![]() Client: U All No Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: November 14, 2016 | Permit id: 549724 | |||||
SCORE 100 Relocate (25) fire sprinklers. ![]() ![]() Client: U All No Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: January 31, 2017 | Permit id: 695294 | |||||
SCORE 100 Alteration: interior plumbing for professional offices and personal services from the basement through the fourth floor space for use as banquet hall for more than people (night club private club) - the installation will comply with the philadelphia plumbing code 2004 ![]() ![]() Client: U All No Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 700072 | |||||
SCORE 78 To amend permit ap#641443 for interior and exterior renovation including framing, storefront, terraces, and facade repairs studio fit out, egress improvement, spray-fire resistant material application, accessibility upgrades, new finishes, window replacement, and new lawful occupancy of banquet hall in conjunction with prior phase 1 permit #549724. ![]() ![]() Client: U All No Llc | Permit type: Administrative permit | Permit status: Completed | Completion date: June 30, 2017 | Permit id: 706597 | |||||
SCORE 89 Install of 73 split systems with condensing units at roof level; installation of five (5) packaged systems ranging from 7. 5 to tons per plans. Separate permits required for all electrical and plumbing work. Separate building permit required for any structural work for support of new units dunnage. ![]() ![]() Client: U All No Llc | Permit type: Mechanical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 707721 | |||||
SCORE 100 Curb trap, fai, main drain & area drain pa20162880289 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. ![]() ![]() Client: U All No Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 729304 | |||||
For the amendment of permit ap#641443 to revise configuration of 4th floor to increase size of the proposed banquet hall, with reduction in for studio area, and the addition of an exterior, steel-framed stair tower. ![]() Client: U All No Llc | Permit type: Administrative permit | Permit status: Completed | Completion date: November 3, 2017 | Permit id: 800577 | |||||
SCORE 89 Install 400amp mlb panel in new electrical room with disconnect&2 disconnect for elevator. 4th fl wiring of main panel and subpanels to units on 4th fl. Annex units power to 2 units as per 2008 nec. ![]() ![]() Client: U All No Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 821591 | |||||
Temporary certificate of occupancy for banquet hall,artist studio artisan industrial,business professional services ![]() Client: U All No Llc | Permit type: Administrative permit | Permit status: Completed | Completion date: November 2, 2017 | Permit id: 826991 | |||||
SCORE 81 Removal of one 15 gallon undergroung storage tank utilized to hold no 4 oil (clossure report to be given to l&i inspector. ![]() ![]() Client: U All No Llc | Permit type: Demolition permit | Permit status: Completed | Completion date: July 1, 2013 | Permit id: 476062 | |||||
Basement: business offices, artisan studios, wood shop, ceramics studio & metal shop(artisan industrial) 1st fl: business offices, artisan studios, wood shop metal shop(artisan industrial) 2nd fl: business offices, artisan studios, srtisan industrial, private physical training (personal services), 3rd fl: artisan studios. 4th fl: vacant. Size and location as per attached plans and tenant space schedule. ![]() Client: U All No Llc | Permit type: Use permit | Permit status: Completed | Completion date: July 9, 2014 | Permit id: 545857 |