SCORE 72 26 Independence Ave Se, Washington, Dc 20003 Soil boring for dewatering activities at cso-019 of dc waters anacostia river tunnel project. 28 mud rotary borings: 12 dewatering wells at 195 feet deep, 8 inches internal diameter; 4 monitoring wells at 132 feet deep, 2 inches internal diameter. 12 contingency wells. Date: March 31, 2014 Contractor: Zach Zill Client: Dc Water | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400046 | |||||
SCORE 72 26 Independence Ave Se, Washington, Dc 20003 Temporary construction trailers for dc waters anacostia river tunnel project. Six trailers total: two single-wide, three double-wide, one triple-wide. Soil erosion control ? Site work already approved, permit # bciv1400011 ( trailers to be removed by 10-1-17) Date: January 22, 2014 Contractor: Zach Zill Client: Impregilo-Healy-Parsons Jv | Permit type: New building | Permit status: Completed | Permit id: B1401123 | |||||
SCORE 72 26 Independence Ave Se, Washington, Dc 20003 Soil boring for ground characterization at cso 019 site of dc water clean rivers div h project. Fifteen borings to approx. El -70. Sonic borings 6 inches diameter. Borings will be identical in means and methods to borings permitted under sb 1500178. Date: March 30, 2015 Contractor: Zach Zill Client: Dc Water Carlton Ray | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500218 | |||||
SCORE 72 26 Independence Ave Se, Washington, Dc 20003 Dc clean rivers anacostia river tunnel project cso 019 support of excavation. Slurry wall soe for excavation of two shafts 117 feet deep from surface, 69 feet 4 inch inside diameter. Slurry wall construction will be 36 inch thick 50 psi reinforced concrete. Ground disturbance and cut/fill volume previously approved under permit bciv1300043. Date: January 27, 2014 Contractor: Zach Zill Client: Dc Water Carlton Ray | Permit type: Sheeting and shoring | Permit status: Permit issued | Permit id: Sh1400018 | |||||
SCORE 72 26 Independence Ave Se, Washington, Dc 20003 Near surface structures for dc water clean rivers project div h - cso 019 site. Construction of intake/ventilation chambers, approach channel and odor control venting facility, and connection to overflow structure. All construction is below-grade sewerage. Sheeting & shoring permit b1506965. Erosion control & stormwater management permitted under bciv1300043. Date: August 10, 2015 Contractor: Zach Zill Client: Dc Water Carlton Ray | Permit type: New building | Permit status: Permit issued | Permit id: B1510807 | |||||
SCORE 72 Date: August 25, 2014 Contractor: Zach Zill Permit status: Permit expired | Expiration date: December 29, 2014 | Permit id: Pa10154711 |