Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 98 28653 Sky Pilot Way, Valley Center, Ca 92082 Reroofing asphalt shingles with asphalt shingles your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 185-273-12-00 | |||||
SCORE 98 473 Eldorado Dr, Escondido, Ca 92025 17 sqft reroof comp to comp shingle (14 sqft sfd and 3 sqft det garage) your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2013-Resalt- | Parcel: 237-210-16-00 | |||||
SCORE 98 14 Via Del Corvo, San Marcos, Ca 92069 31 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt proposed roofing material asphalt manufacturer owens corning brand and model oakridge - amber color (if cool roof required) yes built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 2220600800 | |||||
SCORE 98 9259 Sinsonte Ln, Lakeside, Ca 92040 25 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tiles proposed roofing material concrete tiles manufacturer boral brand and model sunrise color (if cool roof required) multicolor, crrc product id# 0742-0024 built-up roofing assembly system number per attached listing report (if applicable) no specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 3974111900 | |||||
SCORE 98 15376 Pauma Valley Dr, Pauma Valley, Ca 92061 Hra- 45 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: old pioneer litewieght shake profile proposed roofing material: new eagle liteweight capistrano "s" manufacturer: eagles brand and model: capistrano liteweight color (if cool roof required): kings canyon blend built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): crrc 0918-0044 required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 132-360-37-00 | |||||
SCORE 98 9345 El Tejado Rd La Mesa Ca 91941 44 sf reroof std wt concrete tile for existing sfd your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: October 28, 2011 | Permit id: Pds2011-1005-20 | |||||
SCORE 98 323 Cahuka Ct Pauma Valley Ca 92061 34 sf reroof (eagle tile icc esr 19 standard weight tile) and new sheeting for existing sfd your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 30, 2011 | Permit id: Pds2011-1005-20 | |||||
SCORE 98 32409 Kica Ct Pauma Valley Ca 92061 33 sqft reroof from wood shake to concrete tile (icc esr-1900) and to add 7/8 osb sheathing your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 23, 2012 | Permit id: Pds2012-1030-20 | |||||
SCORE 98 32412 Womsi Rd Pauma Valley Ca 92061 36 sqft reroof from wood shake to concrete tile (icc esr-1900) and to add 7/8 osb sheathing your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 16, 2012 | Permit id: Pds2012-1030-20 | |||||
SCORE 98 9345 El Tejado Rd, La Mesa, Ca 91941 44 sf reroof std wt concrete tile for existing sfd your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2011-1005-20 | Parcel: 495-333-14-00 | |||||
SCORE 98 32412 Womsi Rd, Pauma Valley, Ca 92061 36 sqft reroof from wood shake to concrete tile (icc esr-1900) and to add 7 8 osb sheathing your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2012-1030-20 | Parcel: 132-370-37-00 | |||||
SCORE 98 32409 Kica Ct, Pauma Valley, Ca 92061 33 sqft reroof from wood shake to concrete tile (icc esr-1900) and to add 7 8 osb sheathing your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2012-1030-20 | Parcel: 132-370-21-00 | |||||
SCORE 98 323 Cahuka Ct, Pauma Valley, Ca 92061 34 sf reroof (eagle tile icc esr 19 standard weight tile) and new sheeting for existing sfd your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2011-1005-20 | Parcel: 132-370-10-00 | |||||
SCORE 98 7008 Camto De Conejos, Rancho Santa Fe, Ca 92067 90 sf reroof w shake concrete tile icbo: er 5492 hra Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2005-1030-20 | Parcel: 265-220-04-00 | |||||
SCORE 98 15376 Pauma Valley Dr Pauma Valley Ca 92061 - 45 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material old pioneer litewieght shake profile proposed roofing material new eagle liteweight capistrano "s" manufacturer eagles brand and model capistrano liteweight color (if cool roof required) kings canyon blend built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) crrc 0918-0044 required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: December 31, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 98 28653 Sky Pilot Way Valley Center Ca 92082 Reroofing asphalt shingles with asphalt shingles your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 24, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 98 473 Eldorado Dr Escondido Ca 92025 17 sqft reroof comp to comp shingle (14 sqft sfd and 3 sqft det garage) your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: December 6, 2013 | Permit id: Pds2013-Resalt- | |||||
SCORE 98 9259 Sinsonte Ln Lakeside Ca 92040 25 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tiles proposed roofing material concrete tiles manufacturer boral brand and model sunrise color (if cool roof required) multicolor, crrc product id# 0742-0024 built-up roofing assembly system number per attached listing report (if applicable) no specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: July 29, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 98 14 Via Del Corvo San Marcos Ca 92069 31 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt proposed roofing material asphalt manufacturer owens corning brand and model oakridge - amber color (if cool roof required) yes built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) Permit type: Residential alteration-addn | Permit status: Completed | Completion date: August 24, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 98 1922 Vista Grande Rd El Cajon Ca 92019 53 sf re-roof () for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material concrete tile manufacturer eagle brand and model tellacotta gold color (if cool roof required) crrc 0918-0002 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a . Permit type: Addn | Permit status: Completed | Completion date: November 14, 2017 | Permit id: Pds2017-Resalt- |