Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 512136 | |||||
Alteration permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 548746 | |||||
Electrical permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 513998 | |||||
Plumbing permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 540706 | |||||
Electrical permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 513998 | |||||
Alteration permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 548746 | |||||
Mechanical permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 512136 | |||||
Plumbing permit ![]() Client: Temporal Maria S | Permit status: Expired | Permit id: 540706 | |||||
SCORE 88 - remove existing brick front wall, 6 square feet. New framing to be structurally fastened to existing party walls and inspected prior to closing. Foundation wall to extend to first floor at 8 inch width. Physically tie in every 4 feet at adjoining wall. New windows and doors must comply with all glazing requirements of the 2009 international energy conservation code. Install capping, flashing and weep holes as per code requirements. R-19 insulation and sheetrock on interior front wall for finish. An inspection of existing wall to be scheduled with inspector before work starts. ![]() ![]() Client: Temporal Maria S | Permit type: Alteration permit | Permit status: Expired | Completion date: June 4, 2016 | Permit id: 548746 | |||||
SCORE 100 Complete re-wire with 100a service.. Receptacles, 15 switches, 5 smoke detectors and 24 hi-hats... In accordance with 2008 nec for a one family building ![]() ![]() Client: Temporal Maria S | Permit type: Electrical permit | Permit status: Expired | Completion date: August 21, 2014 | Permit id: 513998 | |||||
SCORE 100 Install all rough plumbing to connect 1-kitchen sink, 1-laundry tub, 2-toilets, 1-bath tub & 2-vanities (sfd) pa201415502 self-cerifications are no longer permitted - all excavations & plumbing trenches in excess of 5 in depth must have approved shoring in place at the time of inspection ![]() ![]() Client: Temporal Maria S | Permit type: Plumbing permit | Permit status: Expired | Completion date: June 23, 2014 | Permit id: 540706 | |||||
SCORE 88 2 story 2"x6", 16"oc wood framed wall in rear. 2"x 10" window and door headers, r-19 insulation in exterior wall cavaties. Tyvek underlayment under 1" stucco with wire mesh. ![]() ![]() Client: Temporal Maria S | Permit type: Alteration permit | Permit status: Expired | Completion date: June 4, 2016 | Permit id: 520479 | |||||
SCORE 91 Install new 75,0 btu 90% furnace and 2 ton a c system new duct work ![]() ![]() Client: Temporal Maria S | Permit type: Mechanical permit | Permit status: Expired | Completion date: June 4, 2016 | Permit id: 512136 |